Call centre:

22 201 36 60

Contact us

  • Polish
  • English
  • Eneria
  • Our offer
  • Service and parts
  • Career
  • Our projects
  • Contact
  • About us
    • Eneria
    • Caterpillar®
    • Monnoyeur
  • Our offer
    • Diesel Generator Sets
      • Emergency Power Supply
      • Special Solutions
      • Used Generator Sets
      • Fuel Systems
      • Rental of Generator Sets
    • Comprehensive solutions for Data Centers
      • Emergency power supply for Data Centers
      • Redundant Power Supply For data Centers
      • Photovoltaics & Power Storage Systems for Data Center Facilities
      • Electrical Systems for Data Center
      • Service & maintenance for Data Center
      • References in Data Center
      • UPTIME INSTITUTE certification
    • CATERPILLAR® Engines
      • Industrial Engines
      • Oil & Gas Engines
      • Engines for Railways/Locomotives
      • Accessories for Engines
    • Cogeneration
      • Biogas and Natural Gas
      • SPECIALTY GAS
      • Container Housing
      • Gas turbines: for power generation
      • Gas Power Generation Packages
    • Renewable Energy
      • Photovoltaic solutions
      • Smart grid
    • Marine Solutions
      • Marine Engines and Generator Sets
      • CAT® Propulsion Systems
      • Marine Service
    • Electrical systems
      • High-current systems
      • Low-voltage wiring systems
      • Działalność dodatkowa
    • CAT® Financial
  • Service and parts
    • Service offer
    • Service of generator sets
    • Service of cogeneration units
    • Service of industrial engines
    • Service of railway engines
    • Marine service
    • Genuine CAT® spare parts
    • Ask for parts
    • General renovation
    • Service contracts
  • Our projects
  • Career
  • Contact

UPTIME INSTITUTE certification

Eneria / Our offer / COMPREHENSIVE SOLUTIONS FOR DATA CENTERS / UPTIME INSTITUTE certification

  • UPTIME INSTITUTE certification
  • References in Data Center
  • Service & maintenance for Data Center
  • Electrical Systems for Data Center
  • Photovoltaics & Power Storage Systems for Data Center Facilities
  • Redundant Power Supply For data Centers
  • Emergency power supply for Data Centers
  • Download Data Center catalogue

We have an individual rating recognized by the UPTIME INSTITUTE

CAT® was the first manufacturer to carry out, with participation from the Uptime Institute, an investigation in Data Centers to which it had supplied generator sets. As a result of such analyses a dedicated operating mode was developed for the generator sets, which meets all the requirements for Tier III and IV Certification – Mission Critical Standby. In the Mission Critical Standby mode, the generator sets may work under 100% load for an unlimited number of hours. This guarantees to the Project Owners that the capabilities of generator sets will be fully used, as their operation is optimized for the needs of Data Centers.

The use of Caterpillar generator sets ensures full energy security of Data Centers in terms of both certification and optimum selection of generator sets for the needs of the Customer.

agregat prądotwórczy CAT         

Uptime Institute classification of generator sets

Engine generators for Tier III and IV sites shall not have a limitation on consecutive hours of operation when loaded to ‘N’ demand.

Engine generators that have a limit on consecutive hours of operation at N demand are appropriate for Tier I or II.

Summary of requirements concerning system security for generator sets.

REQUIREMENTS FOR GENERATOR SETS TIER i TIER ii TIER III TIER iV

MODE OF SUPPLYING RATED POWER FOR TAKING OVER DESIGN LOAD

NO SPECIAL REQUIREMENTS, THE GENERATOR SET TAKES OVER DESIGN LOAD UP TO THE RATED POWER LEVEL NO SPECIAL REQUIREMENTS, THE GENERATOR SET TAKES OVER DESIGN LOAD UP TO THE RATED POWER LEVEL THE GENERATOR SET MAY TAKE OVER DESIGN LOAD IN THE CONDITIONS PREVAILING AT THE PLACE OF OPERATION, WITHOUT ANY TIME LIMITATION THE GENERATOR SET MAY TAKE OVER DESIGN LOAD IN THE CONDITIONS PREVAILING AT THE PLACE OF OPERATION, WITHOUT ANY TIME LIMITATION
CONTINUOUS MODE NO ADDITIONAL REQUIREMENTS AS TO LIMITATION ON NUMBER OF WORKING HOURS FULL RATED POWER
PRIME MODE OPTION 1: 70% OF RATED POWER

OPTION 2: HIGHER CAPACITY THAN UNDER OPTION 1, CONFIRMED WITH A DOCUMENT FROM THE MANUFACTURER

STANDBY MODE THIS GENERATOR SET MAY BE USED IN TIER III AND IV SITES IF DOCUMENTS FROM THE MANUFACTURER ARE AVAILABLE; TIER CERTIFICATION DEPENDS ON THE DOCUMENTS FROM THE MANUFACTURER
DE-RATING DUE TO CONDITIONS PREVAILING AT THE PLACE OF OPERATION DE-RATING MAY BE NECESSARY DUE TO CONDITIONS PREVAILING AT THE PLACE OF OPERATION (AMBIENT TEMPERATURE, HEIGHT ABOVE SEA LEVEL) – VERIFICATION AGAINST MANUFACTURER’S REQUIREMENTS IS NECESSARY
Sorce: Accredited Tier Designer Technical Paper. Series: Engine-Generator Ratings accordingto  Uptime Institute

 

For example:

At Data Center Moscow, each CAT® generator set supplies 2 MW of backup power in a compact system. This means that it meets the requirements of the ISO 8528-5 standard and takes over 100% of rated load during the entire year.

 

  • Eneria
  • Our projects
  • Our offer
  • Career
  • Contact
  • Service and parts
  • Ogólne warunki sprzedaży
  • GDPR

Polecamy

  • Wiaty fotowoltaiczne
  • Rozwiązania dla Data Center
  • Kogeneracja CAT
  • Agregaty prądotwórcze CAT Diesel
  • Electrical systems
  • Biogas and Natural Gas
  • Container Housing
  • Moduły monokrystaliczne

Call centre

22 201 36 60

Contact us

Bergerat Monnoyeur sp. z o.o.

Eneria Department
Modlińska 11 Street Izabelin-Dziekanówek
05-092 Łomianki/Warsaw
VAT EU: PL7780022310

Copyrights © 2023 Bergerat Monnoyeur sp. z o.o. All rights reserved.

Contact us


Send