{"id":9162,"date":"2021-10-04T10:16:47","date_gmt":"2021-10-04T08:16:47","guid":{"rendered":"https:\/\/eneria.pl\/?page_id=9162"},"modified":"2021-10-11T13:41:36","modified_gmt":"2021-10-11T11:41:36","slug":"uptime-institute-certification","status":"publish","type":"page","link":"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/","title":{"rendered":"UPTIME INSTITUTE certification"},"content":{"rendered":"<div class=\"mceContentBody mceFrontEnd default\"><h5>We have an individual rating recognized by the UPTIME INSTITUTE<\/h5>\n<p>CAT\u00ae was the first manufacturer to carry out, with participation from the Uptime Institute, an investigation in Data Centers to which it had supplied generator sets. As a result of such analyses a dedicated operating mode was developed for the generator sets, which meets all the requirements for Tier III and IV Certification \u2013 Mission Critical Standby. In the Mission Critical Standby mode, the generator sets may work under 100% load for an unlimited number of hours. This guarantees to the Project Owners that the capabilities of generator sets will be fully used, as their operation is optimized for the needs of Data Centers.<\/p>\n<p>The use of Caterpillar generator sets ensures full energy security of Data Centers in terms of both certification and optimum selection of generator sets for the needs of the Customer.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2109 alignnone\" src=\"https:\/\/eneria.pl\/wp-content\/uploads\/2019\/02\/3512B.jpg\" alt=\"agregat pr\u0105dotw\u00f3rczy CAT\" width=\"344\" height=\"211\" srcset=\"https:\/\/eneria.pl\/wp-content\/uploads\/2019\/02\/3512B.jpg 689w, https:\/\/eneria.pl\/wp-content\/uploads\/2019\/02\/3512B-300x184.jpg 300w\" sizes=\"auto, (max-width: 344px) 100vw, 344px\" \/>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-7952 alignnone\" src=\"https:\/\/eneria.pl\/wp-content\/uploads\/2021\/02\/certyficat.png\" alt=\"\" width=\"136\" height=\"145\" srcset=\"https:\/\/eneria.pl\/wp-content\/uploads\/2021\/02\/certyficat.png 502w, https:\/\/eneria.pl\/wp-content\/uploads\/2021\/02\/certyficat-281x300.png 281w\" sizes=\"auto, (max-width: 136px) 100vw, 136px\" \/><\/p>\n<h5>Uptime Institute classification of generator sets<\/h5>\n<p>Engine generators for Tier III and IV sites shall not have a limitation on consecutive hours of operation when loaded to \u2018N\u2019 demand.<\/p>\n<p>Engine generators that have a limit on consecutive hours of operation at N demand are appropriate for Tier I or II.<\/p>\n<h3><span style=\"font-size: 18pt;\"><strong>Summary of requirements concerning system security for generator sets.<\/strong><\/span><\/h3>\n<table style=\"border-collapse: collapse; width: 100%; height: 330px;\">\n<tbody>\n<tr style=\"height: 85px;\">\n<td style=\"width: 20%; text-align: left; height: 85px;\"><span style=\"font-size: 10pt;\"><strong>REQUIREMENTS FOR GENERATOR SETS<\/strong><\/span><\/td>\n<td style=\"width: 20%; height: 85px;\"><span style=\"font-size: 10pt;\"><strong>TIER i<\/strong><\/span><\/td>\n<td style=\"width: 20%; height: 85px;\"><span style=\"font-size: 10pt;\"><strong>TIER ii<\/strong><\/span><\/td>\n<td style=\"width: 20%; height: 85px;\"><span style=\"font-size: 10pt;\"><strong>TIER III<\/strong><\/span><\/td>\n<td style=\"width: 20%; height: 85px;\"><span style=\"font-size: 10pt;\"><strong>TIER iV<\/strong><\/span><\/td>\n<\/tr>\n<tr style=\"height: 49px;\">\n<td style=\"width: 20%; height: 49px;\">\n<p style=\"text-align: left;\"><strong><span style=\"font-size: 10pt;\">MODE OF SUPPLYING RATED POWER FOR TAKING OVER DESIGN LOAD<\/span><\/strong><\/p>\n<\/td>\n<td style=\"width: 20%; height: 49px;\"><span style=\"font-size: 10pt;\">NO SPECIAL REQUIREMENTS, THE GENERATOR SET TAKES OVER DESIGN LOAD UP TO THE RATED POWER LEVEL<\/span><\/td>\n<td style=\"width: 20%; height: 49px;\"><span style=\"font-size: 10pt;\">NO SPECIAL REQUIREMENTS, THE GENERATOR SET TAKES OVER DESIGN LOAD UP TO THE RATED POWER LEVEL<\/span><\/td>\n<td style=\"width: 20%; height: 49px;\"><span style=\"font-size: 10pt;\">THE GENERATOR SET MAY TAKE OVER DESIGN LOAD IN THE CONDITIONS PREVAILING AT THE PLACE OF OPERATION, WITHOUT ANY TIME LIMITATION<\/span><\/td>\n<td style=\"width: 20%; height: 49px;\"><span style=\"font-size: 10pt;\">THE GENERATOR SET MAY TAKE OVER DESIGN LOAD IN THE CONDITIONS PREVAILING AT THE PLACE OF OPERATION, WITHOUT ANY TIME LIMITATION<\/span><\/td>\n<\/tr>\n<tr style=\"height: 49px;\">\n<td style=\"width: 20%; height: 49px; text-align: left;\"><strong><span style=\"font-size: 10pt;\">CONTINUOUS MODE<\/span><\/strong><\/td>\n<td style=\"width: 40%; height: 147px;\" colspan=\"2\" rowspan=\"3\"><span style=\"font-size: 10pt;\">NO ADDITIONAL REQUIREMENTS AS TO LIMITATION ON NUMBER OF WORKING HOURS<\/span><\/td>\n<td style=\"height: 49px; width: 20%;\" colspan=\"2\"><span style=\"font-size: 10pt;\">FULL RATED POWER<\/span><\/td>\n<\/tr>\n<tr style=\"height: 49px;\">\n<td style=\"width: 20%; height: 49px; text-align: left;\"><strong><span style=\"font-size: 10pt;\">PRIME MODE<\/span><\/strong><\/td>\n<td style=\"width: 20%; height: 49px;\" colspan=\"2\"><span style=\"font-size: 10pt;\">OPTION 1: <strong>70% OF RATED POWER<\/strong><\/span><\/p>\n<p><span style=\"font-size: 10pt;\">OPTION 2: HIGHER CAPACITY THAN UNDER OPTION 1, CONFIRMED WITH A DOCUMENT FROM THE MANUFACTURER<\/span><\/td>\n<\/tr>\n<tr style=\"height: 49px;\">\n<td style=\"width: 20%; height: 49px; text-align: left;\"><strong><span style=\"font-size: 10pt;\">STANDBY MODE<\/span><\/strong><\/td>\n<td style=\"width: 20%; height: 49px;\" colspan=\"2\"><span style=\"font-size: 10pt;\">THIS GENERATOR SET MAY BE USED IN TIER III AND IV SITES IF DOCUMENTS FROM THE MANUFACTURER ARE AVAILABLE; TIER CERTIFICATION DEPENDS ON THE DOCUMENTS FROM THE MANUFACTURER<\/span><\/td>\n<\/tr>\n<tr style=\"height: 49px;\">\n<td style=\"width: 20%; height: 49px; text-align: left;\"><strong><span style=\"font-size: 10pt;\">DE-RATING DUE TO CONDITIONS PREVAILING AT THE PLACE OF OPERATION<\/span><\/strong><\/td>\n<td style=\"width: 80%; height: 49px;\" colspan=\"4\"><span style=\"font-size: 10pt;\">DE-RATING MAY BE NECESSARY DUE TO CONDITIONS PREVAILING AT THE PLACE OF OPERATION (AMBIENT TEMPERATURE, HEIGHT ABOVE SEA LEVEL) \u2013 VERIFICATION AGAINST MANUFACTURER\u2019S REQUIREMENTS IS NECESSARY<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div><span style=\"font-size: 10pt;\">Sorce: Accredited Tier Designer Technical Paper. Series: Engine-Generator Ratings accordingto\u00a0 Uptime Institute<\/span><\/div>\n<p>&nbsp;<\/p>\n<p><strong>For example:<\/strong><\/p>\n<p>At Data Center Moscow, each CAT\u00ae generator set supplies 2 MW of backup power in a compact system. This means that it meets the requirements of the ISO 8528-5 standard and takes over 100% of rated load during the entire year.<\/p>\n<div class=\"flex-video\"><iframe loading=\"lazy\" title=\"9564   EP Power Profile DataSpace ENGLISH\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/3_gJ-HKxmTg?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>&nbsp;<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>We have an individual rating recognized by the UPTIME INSTITUTE CAT\u00ae was the first manufacturer to carry out, with participation from the Uptime Institute, an investigation in Data Centers to which it had [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":9160,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-9162","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>UPTIME INSTITUTE certification - Eneria<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"UPTIME INSTITUTE certification - Eneria\" \/>\n<meta property=\"og:description\" content=\"We have an individual rating recognized by the UPTIME INSTITUTE CAT\u00ae was the first manufacturer to carry out, with participation from the Uptime Institute, an investigation in Data Centers to which it had [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/\" \/>\n<meta property=\"og:site_name\" content=\"Eneria\" \/>\n<meta property=\"article:modified_time\" content=\"2021-10-11T11:41:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/eneria.pl\/wp-content\/uploads\/2019\/02\/3512B.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/\",\"url\":\"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/\",\"name\":\"UPTIME INSTITUTE certification - Eneria\",\"isPartOf\":{\"@id\":\"https:\/\/eneria.pl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/eneria.pl\/wp-content\/uploads\/2019\/02\/3512B.jpg\",\"datePublished\":\"2021-10-04T08:16:47+00:00\",\"dateModified\":\"2021-10-11T11:41:36+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/#primaryimage\",\"url\":\"https:\/\/eneria.pl\/wp-content\/uploads\/2019\/02\/3512B.jpg\",\"contentUrl\":\"https:\/\/eneria.pl\/wp-content\/uploads\/2019\/02\/3512B.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eneria.pl\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Our offer\",\"item\":\"https:\/\/eneria.pl\/en\/offer\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"COMPREHENSIVE SOLUTIONS FOR DATA CENTERS\",\"item\":\"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"UPTIME INSTITUTE certification\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eneria.pl\/#website\",\"url\":\"https:\/\/eneria.pl\/\",\"name\":\"Eneria\",\"description\":\"Eneria\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eneria.pl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"UPTIME INSTITUTE certification - Eneria","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/","og_locale":"en_US","og_type":"article","og_title":"UPTIME INSTITUTE certification - Eneria","og_description":"We have an individual rating recognized by the UPTIME INSTITUTE CAT\u00ae was the first manufacturer to carry out, with participation from the Uptime Institute, an investigation in Data Centers to which it had [&hellip;]","og_url":"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/","og_site_name":"Eneria","article_modified_time":"2021-10-11T11:41:36+00:00","og_image":[{"url":"https:\/\/eneria.pl\/wp-content\/uploads\/2019\/02\/3512B.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/","url":"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/","name":"UPTIME INSTITUTE certification - Eneria","isPartOf":{"@id":"https:\/\/eneria.pl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/#primaryimage"},"image":{"@id":"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/#primaryimage"},"thumbnailUrl":"https:\/\/eneria.pl\/wp-content\/uploads\/2019\/02\/3512B.jpg","datePublished":"2021-10-04T08:16:47+00:00","dateModified":"2021-10-11T11:41:36+00:00","breadcrumb":{"@id":"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/#primaryimage","url":"https:\/\/eneria.pl\/wp-content\/uploads\/2019\/02\/3512B.jpg","contentUrl":"https:\/\/eneria.pl\/wp-content\/uploads\/2019\/02\/3512B.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/uptime-institute-certification\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eneria.pl\/en\/"},{"@type":"ListItem","position":2,"name":"Our offer","item":"https:\/\/eneria.pl\/en\/offer\/"},{"@type":"ListItem","position":3,"name":"COMPREHENSIVE SOLUTIONS FOR DATA CENTERS","item":"https:\/\/eneria.pl\/en\/offer\/comprehensive-solutions-for-data-centers\/"},{"@type":"ListItem","position":4,"name":"UPTIME INSTITUTE certification"}]},{"@type":"WebSite","@id":"https:\/\/eneria.pl\/#website","url":"https:\/\/eneria.pl\/","name":"Eneria","description":"Eneria","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eneria.pl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/eneria.pl\/en\/wp-json\/wp\/v2\/pages\/9162","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eneria.pl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/eneria.pl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/eneria.pl\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/eneria.pl\/en\/wp-json\/wp\/v2\/comments?post=9162"}],"version-history":[{"count":4,"href":"https:\/\/eneria.pl\/en\/wp-json\/wp\/v2\/pages\/9162\/revisions"}],"predecessor-version":[{"id":9337,"href":"https:\/\/eneria.pl\/en\/wp-json\/wp\/v2\/pages\/9162\/revisions\/9337"}],"up":[{"embeddable":true,"href":"https:\/\/eneria.pl\/en\/wp-json\/wp\/v2\/pages\/9160"}],"wp:attachment":[{"href":"https:\/\/eneria.pl\/en\/wp-json\/wp\/v2\/media?parent=9162"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}